Its use is available in static and transient analysis.
On the other hand, in case a seepage analysis is carried out, the Initial head/PWP tool will be visualized instead of the Restart one. The Initial head/PWP tool allows adding both the total head and the pore water pressure results from an specified file the user has loaded. The use process is ahead.
1. First of all, it is necessary to load the .rcf file. This file has been previously created from another model.
2. Now, once the file has been loaded, the Initial Head/PWPbox has to be fulfilled. In this respect, CivilFEM will take into account the total head and the pore water pressure results from the Initial_State file, which correspond to a model previously solved in whatever circumstances.
Its use is available in static and transient analysis.