CFVR2806 - Bending + Axial force checking according to IS456
Check a concrete beam subjected to Bending + Axial force according to IS456
A fixed beam which has a pipe reinforced concrete section is subjected to an axial compression force of 70.820 Mp and a bending moment of 52.620 m*Mp.
The aim of the example is to obtain the check criterion according to IS456.
Element types used in the model: BEAM3 Needed CivilFEM Modules: |
|
| Model Statistics | |
| Number of elements | 4 |
| Number of nodes | 5 |
| Number of civil materials | 2 |
| Number of cross sections | 1 |
| Number of shell vertices | 0 |
Log file: CFVR2806.DAT
FINISH ~CFCLEAR,,1 NomFile='CFVR2806' /TITLE,%NomFile%, BENDING + AXIAL FORCE CHECKING ACCORDING TO IS456 ! ------------------------------------------------------------------------------------- ! Initial data ! ------------------------------------------------------------------------------------- ! CivilFEM SETUP ~UNITS,,LENG,M ~UNITS,,TIME,S ~UNITS,,FORC,MP ~CODESEL,EC3-92,IS456,,,EC8-94 ! Preprocessor /PREP7 ! Material Definition ~CFMP,1,LIB,CONCRETE,IS456,M25 ~CFMP,2,LIB,REINF,IS1786,Fe415 ! Element Type Definition ET,1,Beam3 ! Element Type 1: 2D Beam ! Cross-section definition ~CSECDMS,1,PIPE,1,0.6,0.15 ! Reinforcement definition ~RNFDEF,1,1,2,1,0,0.046,0.5120E-02, ! Total Reinf.area=51.2cm^2 ! Beam & Shell property ~BMSHPRO,1,BEAM,1,1,,,3,1,0,,Beam property ! Model N,1 N,5,5 FILL,1,5 E,1,2 EGEN,4,1,1,1 ! Boundary conditions D,1,ALL,0 /SOLU ! Solution M=52.620 ! 52.620 m*Mp bending moment H=-70.820 ! 70.820 Mp axial force F,5,FX,H F,5,MZ,M SOLVE ! Calculation /POST1 ! Postprocessor ~CFSET,,1 ! Read first load step ! Bending + Axial checking for pipe ~CHKCON,2DB,,0 !-------------------------------------------------------------------------------------- ! DATA CHECK !-------------------------------------------------------------------------------------- ! Data comparision number NComp = 2 NComp_ch = 0 ! Matrix dim. *DIM,LABEL,CHAR,Ncomp,1 *DIM,LABEL_CH,CHAR,Ncomp_ch,1 *DIM,VALUE,,Ncomp,3 *DIM,VALUE_CH,CHAR,Ncomp_ch,3 *DIM,TOLER,,Ncomp,2 ! Labels LABEL(1,1) = 'CRTC2D_I' LABEL(2,1) = 'CRTC2D_J' ! Correct Values VALUE(1,1)=1.173 VALUE(2,1)=1.173 ! Comparison ~PLLSCON,CRT_TOT *GET,VALUE(1,2),ELEM,4,ETAB,CFETAB_I ~PLLSCON,CRT_TOT *GET,VALUE(2,2),ELEM,4,ETAB,CFETAB_J ! Warning and error tolerances TOLER( 1, 1)= 5E-02 $ TOLER( 1, 2)= 5E-02 TOLER( 2, 1)= 5E-02 $ TOLER( 2, 2)= 5E-02 !-------------------------------------------------------------------------------------- ! Results Comparison !-------------------------------------------------------------------------------------- COMPARA.MAC |
Results
| Label | Target | CivilFEM | Ratio | Tolerance |
| CRTC2D_I | 1.173 | 1.1833 | 0.991 | 0.05 |
| CRTC2D_J | 1.173 | 1.1833 | 0.991 | 0.05 |
Contains proprietary and confidential information of Ingeciber, S.A.