Left

CivilFEM Online Help

Right

~PRSTL

 

~PRSTL, Level, LabNode, ENTNUM, Result

Lists results of steel checking for beam elements and solid sections.

POST1: Steel Checking

Level

Results output level. Valid labels are:

 BASIC

Design results.

DETAILED

Detailed design result .

LabNode

Element end or solid section to be listed.

For beam elements, valid labels are:

I

I section.

J

J section.

BOTH

Both sections (default option).

For solid sections labels are the following:

N

Number of solid section.

ALLS

All solid sections.

ENTNUM

Number of entity (element) to be listed. It is only valid for beam elements.

ALL

Lists results in all selected elements (default option).

N

Number of element for which the result is listed.

Result

Result to be listed.

ALL

All available results (default option).

Parameter

Result parameter to be listed. See command ~PLLSSTL for the different parameter results to be listed depending on the type of checking.

EFFE

Effective section parameters. This list is only available for class 4 sections (Eurocode 3 and British Standard).

Notes

- This command list results for checking of selected beam elements and solid sections. If results are coming from an alternatives envelop, the alternatives that produced the listed value are also indicated.

- The effective section parameters can only be listed if the checking code used calculates these values.

Menu Paths

Main Menu > CIVIL Postprocessor > Code Checking > ###### > BEAM RESULTS: List Results

Where ###### represents the active structural steel code.