Left

CivilFEM Online Help

Right

~PRSTR

 

~PRSTR, LabSTR, LabNode, LabTYP, ENTNUM, LabSTR2, LabSTR3, LabSTR4, LabSTR5, LabSTR6

Lists stresses and strains in beam and shell elements and solid sections.

POST1: Beam & Shell Utilities

LabSTR

Entity to be listed. Allowable values are:

SX

SX stresses

SY

SY stresses

SZ

SZ stresses

SXY

SXY stresses

SYZ

SYZ stresses

SXZ

SXZ stresses

S

All stresses

EPX

eX elastic strains

EPY

eY elastic strains

EPZ

eZ elastic strains

EPXY

eXY elastic strains

EPYZ

eYZ elastic strains

EPXZ

eXZ elastic strains

EP

All elastic strains

LabNode

Cross section or element vertex to be listed. For beam elements cross sections, valid labels are:

I

I section.

J

J section.

BOTH

Both sections (default option).

For shell element vertices, valid labels are the following:

I

Vertex I

J

Vertex J

K

Vertex K

L

Vertex L

ALL

All vertices (default option).

For solid sections, labels are the following:

N

Number of solid section.

ALLS

All solid sections (default option).

LabTYP

List type.

POINTS

List in all points of the section (default option).

PLATES

List in all plates of the section. Only valid for beam elements.

TESSELUM

List in all tessella of the section. Only valid for beam elements.

REINF

List in all reinforcements of section. Only valid for beam elements.

ENTNUM

It depends on the LabTYP label.

ALL

List results in all points, plates, tessella and reinforcements of the section (default option). For shell elements the results are listed for points 1 (top fiber) and 2 (bottom fiber).

MINMAX

List of maximum and minimum values of the section. It is only valid if LabTYP = POINTS.

N

Number of entity to be listed (point, plates, reinforcement or tessella).

LabSTR2, LabSTR3, LabSTR4, LabSTR5, LabSTR6

Additional stresses and strains to be listed.

Notes

- This command lists stresses and strains in selected beam and shell elements and in the indicated solid section. For beam elements, only SX and EPSX are available.

- The shell elements have two points that represent the top fiber (point 1) and bottom fiber (point 2) of the element.

Menus Path

Main Menu > CIVIL Postprocessor > Shell Utilities > LIST RESULTS: Stress & Strain

Main Menu > CIVIL Postprocessor > Code Checking > ###### > BEAM RESULTS: Beam Utilities > LIST RESULTS: Stress & Strain

Where ###### represents the active code (reinforced concrete or structural steel).